1500 kVA Three-Phase Distribution Transformer

Product Details
Customization: Available
Application: Power, Lighting, Audio
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
Find Similar Products

Basic Info.

Model NO.
S11-M-1500/6.3
Cooling Method
Oil-immersed Type Transformer
Winding Type
Multi-winding Transformer
Coil Structure
Toroidal
Transport Package
Export Worthy Packing
Specification
ISO9001, ISO14001, CE Apply for IEC, JB, ANSI
Trademark
EACHER
Origin
Zhejiang, China
Production Capacity
1000 Per Year

Product Description

Specifications

6.3/1500 kVA Full-sealed Distribution Transformer:
1) CTQC, CE, ISO9001, ISO14001
2) Apply for IEC, GB, ANSI
3) Low losses

6.3kV/1500 kVA Full-sealed Distribution Transformer
Introduction to Products
Its core is made of quality cold-rolled silicon sheet and is of a full-miter non-puncture structure and its coil is made of quality oxygen-free copper. It is artistic in appearance and safe in running and is widely used in transmission and distribution of industrial and agriculturalist.
Main Function And Features
It adopts radiator oil tank of corrugated sheet type or expansion type. As it doesn't need oil conservator, the height of transformer is reduced, and as the transformer oil doesn't contact with air, the oil ageing is retarded, thus prolonging the service life of transformer. The no-load loss of Model S10-M is 20% lower than that of Model S9-M, and S11-M is 30% lower than S9-M. The transformers are high in reliability, advanced in performance and rational in economical indexes. The oil tank is diversified in types and looks artistic and elegant.

Rated power
(kVA)

High Voltage
(kV)

H.V Tap range

Low Voltage
(kV)

Connection Symbol

Short-Circuit Impedance
(%)

No-load Loss
(W)

On-Load Loss
(W)

No-load Current
(%)
9 Type 10 Type 11 Type 9 Type 10 Type 11 Type
30 6
6.3
10
10.5
±5%
±2×2.5%
0.4 Dyn11
Yyn0
4 130 110 100 600 600 600 2.1
50 170 150 130 870 870 870 2
63 200 180 150 1040 1040 1040 1.9
80 250 200 180 1250 1250 1250 1.8
100 290 230 200 1500 1500 1500 1.6
125 340 270 240 1800 1800 1800 1.5
160 400 310 280 2200 2200 2200 1.4
200 480 380 340 2600 2600 2600 1.2
250 560 460 400 3050 3050 3050 1.2
315 670 540 480 3650 3650 3650 1.1
400 800 650 570 4300 4300 4300 1
500 960 780 680 5150 5150 5150 1
630 4.5 1200 920 810 6200 6200 6200 0.9
800 1400 1120 980 7500 7500 7500 0.8
1000 1700 1320 1150 10300 10300 10300 0.7
1250 1950 1560 1360 12000 12000 12000 0.6
1600 2400 1880 1640 14500 14500 14500 0.6
2000 5 2830 2270 1940 17140 17140 17140 0.6
2500 3350 2690 2300 20260 20260 20260 0.5

Rated power
(kVA)
Weight 
(kg)
Overall dimension(mm) Gauge
(mm)
Active
part
Oil total L W
30 180 85 310 750 720 930 400×400
50 210 90 420 780 740 950 400×400
63 280 110 520 800 750 1000 400×400
80 310 110 520 820 770 1040 400×400
100 340 120 560 825 790 1020 550×550
125 380 130 670 830 790 1120 550×550
160 480 140 770 1070 670 1085 550×550
200 560 160 890 1140 740 1160 550×550
250 670 180 1070 1210 790 1200 550×550
315 750 230 1230 1380 900 1230 550×550
400 930 250 1450 1380 900 1300 550×550
500 1070 260 1670 1490 1000 1320 550×550
630 1290 320 1960 1570 1030 1390 660×660
800 1590 350 2340 1620 1050 1460 660×660
1000 1740 450 2760 1760 1190 1590 660×660
1250 2080 490 3200 1780 1140 1670 660×660
1600 2530 640 3950 1970 1290 1750 820×820
2000 3000 800 4890 2100 2050 2000 820×820
2500 3300 1180 6280 2330 2210 2150 820×820
Company Introduction
1500 kVA Three-Phase Distribution Transformer 1500 kVA Three-Phase Distribution Transformer
1500 kVA Three-Phase Distribution Transformer
1500 kVA Three-Phase Distribution Transformer

1500 kVA Three-Phase Distribution Transformer
Shenda ( In full: Shenda Electric Group Co.,Ltd.)  is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.).  Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.

Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC).
shendaelectric.en.made-in-china.com

Certifications

100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR
1500 kVA Three-Phase Distribution Transformer

Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test

C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).
Projects on Site
1500 kVA Three-Phase Distribution Transformer 1500 kVA Three-Phase Distribution Transformer
Packaging and transportation

1500 kVA Three-Phase Distribution Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier