11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

Product Details
Customization: Available
Application: Power
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
  • 11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
Find Similar Products

Basic Info.

Model NO.
SS-1500(1000+500)/11(6.6)-(1.05+0.415)
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
U
Brand
Eacher
Service Condition
Indoor/Outdoor
Tap Changer
off Load – with Limit Switch
Cooling Type
Onan
Core Structure
Toroidal
High Voltage Range
11kv
Iron Core
Silicon Sheet
Loss
Low Loss
Tap Range
+2.5%, -7.5% (5X2.5% Steps)
Altitude
Less Than or Equal To1000m
Ambient Temperature
-10 to +45 Centigrade
Vector Group
Dyn11yn11
Winding Material
Copper
Bushing
Porcelain
Sound Level
65
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan City, Zhejiang Province, China
Production Capacity
6000sets Per Year

Product Description

Product Description
11kv 1500kva Tertiary Voltage Outdoor Oil immersed Power Transformer

11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

Introduction
    The performance of our S9 S10 S11 series 20kV and 35kV three-phase oil-immersed transformer conform to the standard of GB 1094-1996 "Power Transformer " and GB/T6451-2008 "Technical Parameter and requirements of Three-phase Oil-immersed Power Transformer". The iron core is made of quality cold -rolled silicon steel sheet , and the coil is made of quality oxygen-free copper, featuring good outlook and safe running . The products are widely used in power transmission and distribution of industrial and agricultural power networks.

Main function and features
     High reliability, advanced level of performances, reasonable economical indicators.
    The core joints are of stepped shape with this steps , and the surface of the core is coated with cured     paint to lower losses and noises.
    The winding has novel structure and its oil passage is reasonable designed composition. Its newly designed insulation structure helps enhance its mechanical strength and this short-circuit withstanding ability .
      The oil tank is in various types , all have good outlook .

Rated power
(kVA)

High Voltage
(kV)

H.V Tap range

Low Voltage
(kV)

Connection Symbol

Short-Circuit Impedance
(%)

No-load Loss
(W)

On-Load Loss
(W)

No-load Current
(%)
9 Type 10 Type 11 Type 9 Type 10 Type 11 Type
30 6
6.3
10
10.5
±5%
±2×2.5%
0.4 Dyn11
Yyn0
4 130 110 100 600 600 600 2.1
50 170 150 130 870 870 870 2
63 200 180 150 1040 1040 1040 1.9
80 250 200 180 1250 1250 1250 1.8
100 290 230 200 1500 1500 1500 1.6
125 340 270 240 1800 1800 1800 1.5
160 400 310 280 2200 2200 2200 1.4
200 480 380 340 2600 2600 2600 1.2
250 560 460 400 3050 3050 3050 1.2
315 670 540 480 3650 3650 3650 1.1
400 800 650 570 4300 4300 4300 1
500 960 780 680 5150 5150 5150 1
630 4.5 1200 920 810 6200 6200 6200 0.9
800 1400 1120 980 7500 7500 7500 0.8
1000 1700 1320 1150 10300 10300 10300 0.7
1250 1950 1560 1360 12000 12000 12000 0.6
1600 2400 1880 1640 14500 14500 14500 0.6
2000 5 2830 2270 1940 17140 17140 17140 0.6
2500 3350 2690 2300 20260 20260 20260 0.5

Rated power
(kVA)
Weight 
(kg)
Overall dimension(mm) Gauge
(mm)
Active
part
Oil total L W
30 180 85 310 750 720 930 400×400
50 210 90 420 780 740 950 400×400
63 280 110 520 800 750 1000 400×400
80 310 110 520 820 770 1040 400×400
100 340 120 560 825 790 1020 550×550
125 380 130 670 830 790 1120 550×550
160 480 140 770 1070 670 1085 550×550
200 560 160 890 1140 740 1160 550×550
250 670 180 1070 1210 790 1200 550×550
315 750 230 1230 1380 900 1230 550×550
400 930 250 1450 1380 900 1300 550×550
500 1070 260 1670 1490 1000 1320 550×550
630 1290 320 1960 1570 1030 1390 660×660
800 1590 350 2340 1620 1050 1460 660×660
1000 1740 450 2760 1760 1190 1590 660×660
1250 2080 490 3200 1780 1140 1670 660×660
1600 2530 640 3950 1970 1290 1750 820×820
2000 3000 800 4890 2100 2050 2000 820×820
2500 3300 1180 6280 2330 2210 2150 820×820
Certifications
11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics
11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.

11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.

11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection

11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).

Packaging and transportation
11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance

11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

FAQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier