Forced Oil Water Cooled Series Rectifier Transformer

Product Details
Customization: Available
Phase: Three
Core: Core-type Transformer

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
Find Similar Products

Basic Info.

Model NO.
ZSSP-9000/35
Winding Type
Two-winding Transformer
Certification
ISO9001-2000
Usage
Rectifier Transformer
Winding Material
Copper
Certificates
Ctqc, CE, ISO9001, ISO14001, Cesi
Transport Package
Sea Worthy Packing
Specification
ISO9001, ISO14001, CE Apply for IEC, JB, ANSI
Trademark
EACHER
Origin
Zhejiang, China
Production Capacity
1000 Per Year

Product Description

Specifications

Rectifier Transformer
1) Matching with intermediate frequency induction furnace
2) ISO9001, ISO14001, CE



General
Rectifier transformers are combined with a diode or thyristor rectifier. The applications range from very large aluminum electrolysis to various small and medium size operations. The transformers may have a built-in or separate voltage regulation unit for direct output regulation of diode rectifiers, and correspondingly a power factor improvement with a thyristor rectifiers.

Features:
1) Low loss
2) Low noise
3) High efficiency
4) Low partial discharge
5) Strong mechanical strength and short-circuit withstand ability.
6) Operation reliability
7) Easy maintenance
8) Pretty outline and compact structure
9) 100% guaranteed no leakage

Brief specification
1) Voltage class: 6~110 KV
2) Capacity: 630 kVA to 120, 000 kVA
3) Short-circuit impedance: 4.5~21%
Losses: No-load losses is fully comply with IEC standard requirements

Application:
1) Aluminum smelting
2) Magnesium smelting
3) Copper smelting
4) Zinc smelting
5) The largest installations are those for aluminum electrolysis with several transformer/rectifier units in parallel operation to achieve the required DC current, in all cases the rectifier can be with diodes or thyristors.
Type Rated power
(kVA)
Rated Voltage(V) Connection 
Symbol
Weight(kg) Overall Dimension
L×W×H
(mm)
Gauge
(mm)
Line side Valve side Active part Oil Total
ZSSP-800/10 800 10000 400 Dyn11 1580 660 3240 2160×1625×1855 820
ZSSP-2000/35 2000 35000 400 Yyn0 3320 1280 5735 2600×1260×2740 1070
ZSSP-4000/35 4000 35000 950 Dd0y11 5410 2040 9540 2570×1745×2720 1475
ZSSP-6300/35 6300 35000 1000 D(±7.5 º)dyn 8600 4860 18260 3340×1875×2720 1475
ZSSP-7000/35 7000 35000 950 Dd0y11 8570 3390 14700 3185×985×3475 1475
ZSSP-8000/22 8000 22000 950 Dd0y11 8640 3340 14710 3210×1905×3375 1475
ZSSP-8000/35 8000 35000 950 Dd0y11 9170 3590 15520 3340×1870×3490 1475
ZSSP-9000/35 9000 35000 950 Dd0y11 9920 4070 15740 3240×1915×3720 1475
ZSSP-10000/35 10000 35000 1000 D(±7.5º)dyn 11090 4400 18850 3410×1915×3845 1475

Certifications
Forced Oil Water Cooled Series Rectifier Transformer

Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics
Forced Oil Water Cooled Series Rectifier Transformer
Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.

Forced Oil Water Cooled Series Rectifier Transformer
Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.

Forced Oil Water Cooled Series Rectifier Transformer
Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection

Forced Oil Water Cooled Series Rectifier Transformer
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).


Packaging and transportation
Forced Oil Water Cooled Series Rectifier Transformer



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
Forced Oil Water Cooled Series Rectifier Transformer
Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance

Forced Oil Water Cooled Series Rectifier Transformer

RFQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now