IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer

Product Details
Customization: Available
Type: Box Transformer
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
  • IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
Find Similar Products

Basic Info.

Model NO.
YBS11-750/11
Transport Package
Export Worthy Packing
Specification
CTQC, ISO9001, ISO14001, CE, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan, Zhejiang, China
Production Capacity
10000 Per Year

Product Description

IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer


IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer

Shenda ( In full: Shenda Electric Group Co.,Ltd.)  is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.).  Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.

Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC). 

shendaelectric.en.made-in-china.com

Product Info
IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer

Mobile Substation Specifications
YB Series Cubicle Substation
Serialization, modularization, multiple functions, complete facility, small volume.
 
Configuration Power
(kVA)
W H D W1 D1 D2 H1 Weight
(kg)
Standard
π
configuration
≤125 2000 1580 1116 1180 508 575 1240 2000
160~500 2000 1580 1350 1330 508 655 1340 2950
630 2000 1710 1560 1420 632 775 1480 3400
800 2000 1710 1690 1420 632 775 1480 3600
1000 2000 1710 1820 1420 632 815 1480 4000
1250 2000 1710 1840 1560 632 795 1480 4800
1600 2205 1710 1920 1680 632 920 1520 5700
Extra
π
configuration
≤125 2200 1900 1240 1180 632 575 1240 2200
160~500 2200 1900 1474 1330 632 655 1340 3150
630 2200 1900 1560 1420 632 775 1480 3600
800 2200 1900 1690 1420 632 775 1480 3800
1000 2200 1900 1780 1420 632 815 1480 4200

Certifications

IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer

100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

Test lab And Inspection
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test

C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in  the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).

IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
Client inspection
IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation TransformerIEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer

IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation TransformerIEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer


Transportation
IEEE IEC ISO CE 20 Years Professional Cubicle Type Substation Transformer
























 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier