Ground Mounted Hermitrically Sealed 10kv Distribution Transformers

Product Details
Customization: Available
Application: Power
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
  • Ground Mounted Hermitrically Sealed 10kv Distribution Transformers
Find Similar Products

Basic Info.

Model NO.
S11
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001
Usage
Power Transformer
Frequency Characteristics
Low Frequency
Shape of Core
U
Brand
Eacher/Shenda
Cooling Type
Ofwf/Onan
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER/SHENDA
Origin
Jiangshan City, Zhejiang Province, China

Product Description

Basic Info.
Model NO.: S11-M-2000/10
Usage: Light, Industry, Construction, Digital Products, Vehicle
Output Type: Triple
Driving Method: LED Constant Current
Circuit Structure: PWM Controlled
Coil Structure: Toroidal
Packaging Details: Export Worthy Packing
Coil Number: Other
Certificates: Ctqc, CE, ISO, Cesi
Frequency: 50Hz or 60Hz
Export Markets: Global
Additional Info.
Trademark: EACHER
Packing: Export Worthy Packing
Standard: ISO9001, ISO14001, CE Apply for IEC, JB, ANSI
Origin: Zhejiang, China (Mainland)
Production Capacity: 10000 PCS/Year
Product Description

Features:

1) Amount of local discharged: The apparent discharge amount is less than 80pC under 1.5 times of rated voltage;

2) Noise: Products of 63MVA and below is lower than 58 dB (AN);

3) Power loss: No-load loss is 30% lower than that of IEC standard;

4) Reliability: All in-service products have no damages or oil leakage occurred;

Application:

60 ~220 kV power system of power plant, substation, mining enterprise and etc.

Technologies:

Design: Relative developed software are adopted in Electromagnetic calculations, strength analysis, leakage magnetic distribution, its electro-dynamic force and electrical insulation.

Manufacture:

Core: Effectively upgrade transformer's no-load performance by below methods:

1) The core is made of high-permeable grain-orientated top quality cold-rolled silicon sheet and the material is cut with advanced Germany Geoge GmbH automatic shear line with the cut burs controlled within 0.02mm.

2) The silicon sheet fabrication adopts "no-upper yoke lapped' technology and all lapped joints of the silicon sheet are 45 full-miters. The laminated core sheets are integrally pressed and adhered with epoxy resin to make the three leg two-yoke core a strong and flat integral one with good verticality precision, this effectively improves no-load performance and reduces noises.

3) Bracing plates are used as support between coil leg and inner coil. The iron yoke is tied with epoxy resin-impregnated glass fiber band, and the lower section of oil tank is tightened with counter-pressure bolts. The upper iron and the upper section of oil tank are fixed at three locations. Hence the body inside the oil tank can withstand the vibration during transportation without any shift.

Winding:

1) The high-voltage (HV) coil adopts an interleaved-continuous structure to improve the voltage characteristics under impact voltage and make voltage evenly distributed. All stays and pads are chamfered to keep highly reliable insulation.

2) In the transformer winding there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. The HV and MV regulation system are independently provided with voltage-regulating winding to balance the ampere turn of each winding, effectively lower the axial electrodynamic force generated at short-circuit of transformer and improve abrupt short-circuit withstanding capacity.

3) The winding adopts radial "0" margin designed, between the core and the paper sleeve of LV winding, and between the LV, HV, voltage-regulating windings, as well as before insertion of stays and shroud plate they are fully dried and tightly matched to ensure extremely good compactness and concentricity of the entire winding.
Rated power
(kVA)

High Voltage
(kV)

H.V Tap range

Low Voltage
(kV)

Connection Symbol

Short-Circuit Impedance
(%)

No-load Loss
(W)

On-Load Loss
(W)

No-load Current
(%)
9 Type 10 Type 11 Type 9 Type 10 Type 11 Type
30 6
6.3
10
10.5
±5%
±2×2.5%
0.4 Dyn11
Yyn0
4 130 110 100 600 600 600 2.1
50 170 150 130 870 870 870 2
63 200 180 150 1040 1040 1040 1.9
80 250 200 180 1250 1250 1250 1.8
100 290 230 200 1500 1500 1500 1.6
125 340 270 240 1800 1800 1800 1.5
160 400 310 280 2200 2200 2200 1.4
200 480 380 340 2600 2600 2600 1.2
250 560 460 400 3050 3050 3050 1.2
315 670 540 480 3650 3650 3650 1.1
400 800 650 570 4300 4300 4300 1
500 960 780 680 5150 5150 5150 1
630 4.5 1200 920 810 6200 6200 6200 0.9
800 1400 1120 980 7500 7500 7500 0.8
1000 1700 1320 1150 10300 10300 10300 0.7
1250 1950 1560 1360 12000 12000 12000 0.6
1600 2400 1880 1640 14500 14500 14500 0.6
2000 5 2830 2270 1940 17140 17140 17140 0.6
2500 3350 2690 2300 20260 20260 20260 0.5

Rated power
(kVA)
Weight 
(kg)
Overall dimension(mm) Gauge
(mm)
Active
part
Oil total L W
30 180 85 310 750 720 930 400×400
50 210 90 420 780 740 950 400×400
63 280 110 520 800 750 1000 400×400
80 310 110 520 820 770 1040 400×400
100 340 120 560 825 790 1020 550×550
125 380 130 670 830 790 1120 550×550
160 480 140 770 1070 670 1085 550×550
200 560 160 890 1140 740 1160 550×550
250 670 180 1070 1210 790 1200 550×550
315 750 230 1230 1380 900 1230 550×550
400 930 250 1450 1380 900 1300 550×550
500 1070 260 1670 1490 1000 1320 550×550
630 1290 320 1960 1570 1030 1390 660×660
800 1590 350 2340 1620 1050 1460 660×660
1000 1740 450 2760 1760 1190 1590 660×660
1250 2080 490 3200 1780 1140 1670 660×660
1600 2530 640 3950 1970 1290 1750 820×820
2000 3000 800 4890 2100 2050 2000 820×820
2500 3300 1180 6280 2330 2210 2150 820×820
Company Introduction
Ground Mounted Hermitrically Sealed 10kv Distribution Transformers Ground Mounted Hermitrically Sealed 10kv Distribution Transformers
Ground Mounted Hermitrically Sealed 10kv Distribution Transformers
Ground Mounted Hermitrically Sealed 10kv Distribution Transformers

Ground Mounted Hermitrically Sealed 10kv Distribution Transformers
Shenda ( In full: Shenda Electric Group Co.,Ltd.)  is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.).  Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.

Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC).
shendaelectric.en.made-in-china.com

Certifications

100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR
Ground Mounted Hermitrically Sealed 10kv Distribution Transformers

Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test

C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).
Projects on Site
Ground Mounted Hermitrically Sealed 10kv Distribution Transformers Ground Mounted Hermitrically Sealed 10kv Distribution Transformers
Packaging and transportation

Ground Mounted Hermitrically Sealed 10kv Distribution Transformers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier