138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate

Product Details
Customization: Available
Application: Power
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
  • 138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
Find Similar Products

Basic Info.

Model NO.
SFZ11-56000/138
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Power Transformer
Frequency Characteristics
Low Frequency
Shape of Core
U
Brand
Eacher
Service Condition
Indoor/Outdoor
Tap Changer
Nltc/Oltc
Cooling Type
Octc or Oltc
Core Structure
Toroidal
High Voltage Range
138kv
Iron Core
Silicon Sheet
Loss
Low Loss
Frequency
60Hz
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan City, Zhejiang Province, China
Production Capacity
5sets Per Year

Product Description

Product Description
138KV power transformer is popular world wide in different industry. It is impact and cost-effient

SFZ11-56000/138

138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate


 
Capacity 56 MVA
Primary voltage 138 kV
Secondary voltage 13.09kV
Frequency 60 Hz
Cooling OFAF

Transformer accessories
On load voltage regulating switch imported from MR,USA
No load voltage regulating switch imported from ABB, USA
High pressure casing imported from PCORE USA
Canadian PCORE low pressure casing





138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate







Certifications
138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate

Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics
138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.

138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.

138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection




138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate



Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).

Packaging and transportation
138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate

Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate
Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance

138kv 56000kVA Two Winding No Load Tap Changing High Voltage Substation Oil-Immersed Power Transformer with Kema Certificate

FAQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier