Basic Info.

Model NO.
S11-31500/35
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Kou Type
Brand
Eacher
Service Condition
Indoor/Outdoor
Tap Changer
Nltc/Oltc
Cooling Type
Ofwf/Onan
Core Structure
Toroidal
High Voltage Range
35-38.5kv
Iron Core
Silicon Sheet
Loss
Low Loss
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan City, Zhejiang Province, China
Production Capacity
6000sets Per Year

Product Description

35kv 31500kva three phase two winding no load tap changing oil immersed power transformer

Specifications
1 power transformer
2 ISO9001,ISO14001,OHSAS 18001, CE
3 Apply for IEC, ANSI
4.KEMA

Introduction to Products
The performances of our S9,S10,S11 series 20KV and 35KV three-phase oil-immersed  transformer conform to standards GB1094-1996 "Power Transformer" and GB/T6451-2008 "Technical Parameters and Requirements of Three-phase Oil-immersed Power Transformer". Its core is made of quality cold-rolled silicon sheet and is of a full-miter non-puncture structure and its coil is made of quality oxygen-free copper. It is artistic in appearance and sage in running and is widely used in transmission and distribution of industrial and agricultural networks.

Main Function and Features

High reliabity,advanced levelof performance,reasonable economical indicators
The core joints are of stepped shape with 3 steps,and the surface of the core is coated with cured paint to lower losses and noise.
The winding has novel structure and its oil passage is reasonable designed. Its newly designed insulation structure helps enhance its mechanical strength and the short circuit withstanding ability
The oil tank is in various types,all have good outlook.

Main Technical Parameters for 35kv level,S9,S10,S11 series power transformer
           
Rated Power High Voltage H.V.Tap rang Low Voltage Connection Symbol Short-Circuit Impedance(%) No-load Loss(KW) On-Load Loss(KW) No-load Current(%)
KV KV KV 9type 10type 11type 9type 10type 11type
800 35               38.5 ±5%       ±2×2.5% 6.3               6.6                                    10                          10.5 Yd11 6.5 1250 1110 980 9900 9350 9350 1.05
1000 1490 1320 1160 12200 11500 11500 1
1250 1760 1570 1380 14650 13900 13900 0.9
1600 2130 1900 1660 17650 16600 16600 0.85
2000 2610 2320 2030 19350 18300 18300 0.75
2500 3150 2800 2450 20700 19600 19600 0.75
3150 7 3870 3440 3010 24300 23000 23000 0.7
4000 4640 4120 3610 28800 27200 27200 0.7
5000 5490 4880 4270 33000 31200 31200 0.6
6300 7.5 6570 5840 5110 36900 34900 34900 0.6
8000 Ynd11 9000 8000 7000 40500 38300 38300 0.55
10000 10620 9440 8260 47700 45100 45100 0.55
12500 8 12600 11200 10800 56700 53600 53600 0.5
16000 15300 13600 11900 69300 65500 65500 0.5
20000 18090 16100 14100 83700 79100 79100 0.5
25000 21510 19120 16730 99000 93500 93500 0.4
31500 25650 22800 20000 1E+05 112200 112200 0.4
Transformer accessories
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer

Test lab
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer
Certifications
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power TransformerPackaging and transportation
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer

Part of equipment
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer


Testing center
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer


Customer visiting
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer

Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer35kv 31500kVA Three Phase Two Winding No Load Tap Changing Oil Immersed Power Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier