Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace

Product Details
Customization: Available
Certification: CE, ISO
Place Style: Vertical

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
  • Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
  • Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
  • Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
  • Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
Find Similar Products

Basic Info.

Model NO.
ZSSP-15000/20
Range of Applications
Industrial
Type
Electric Holding Furnace
Usage
Smelting Steel Plant
Fuel
Electric
Transport Package
Sea Worthy Packing
Specification
Total weight 58600kg
Trademark
EACHER
Origin
China
HS Code
8504231100
Production Capacity
5000 Pieces Per Year

Product Description

Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace

UP FURNACE CO., LTD. was founded in 2018, a wholly-owned subsidiary of SHENDA ELECTRIC GROUP CO.,LTD, specializes in R&D, manufacturing, installation, maintenance and transformation of electric furnace products and EPC contracting business of metallurgical engineering. It is an emerging company for various large-scale steelmaking electric arc furnaces, ladle refining furnaces and large non-standard heat treatment furnace and other products in China.

Design and manufacturing capability:
1.Steelmaking electric arc furnace: the main equipment for smelting scrap steel, currently widely used three-phase AC arc smelting, there are three kinds of power configuration of ordinary power, high power and ultra-high power, rated capacity from 1.5t to 150t.
2.Ladle refining furnace: including LF, VD, VOD, VAD, RH and other furnace types, the most commonly used is LF ladle refining furnace, rated capacity from 10t to 300t.
3.Submerged arc furnace: mainly includes ferrosilicon furnace, ferromanganese furnace, ferrochromium furnace, ferronickel furnace, calcium carbide furnace, industrial silicon furnace, etc. The power is from 6300KVA to 48000KVA.
                                  
Steel plant cooperation with Shenda
Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace

Rectifier transformers are combined with a diode or thyristor rectifier. The applications range from very large aluminum electrolysis to various small and medium size operations. The transformers may have a built-in or separate voltage regulation unit for direct output regulation of diode rectifiers , and correspondingly a power factor improvement with a thyristor rectifiers.

Features:
1)    Low loss
2)    Low noise
3)    High efficiency
4)    Low partial discharge
5)    Strong mechanical strength and short-circuit withstand ability .
6)    Operation reliability
7)    Easy maintenance 
8)    Pretty outline and compact structure
9)    100% guaranteed no leakage
Brief specification
1)    Voltage class: 6~110 KV
2)    Capacity : 400KVA to 120,000 KVA
3)    Short-circuit impedance : 4.5~21%
Losses: No-load losses is fully comply with IEC standard requirements
Application:
1)    Aluminum smelting
2)    Magnesium smelting
3)    Copper smelting
4)    Zinc smelting
5)    The largest installations are those for aluminum electrolysis with several transformer/rectifier units in parallel operation to achieve the required DC current, in all cases the rectifier can be with diodes or thyristors.

product series
Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
Product Characteristics_ZSSP-15000/20 
Place of Origin: Zhejiang, China (Mainland)
Brand Name: EACHER
Type:ZSSP-15000/20 
Rate Power:15000 KVA  (long term 20% overload)
Primary voltage:20 KV                                  
Secondary Voltage: (1500±50)V×4 
Secondary Current: 1443A×4
Vector Group: H.V: Delta   L.V: d(-15°),d(+15°), d,yn
Impedance Voltage: 8~9%
Phase: 3 phase input, 12 phase output; 4 group L.V forms equivalent 24 impulse
Rated Frequency: 50Hz
Regulation Type: Non-excitation Tap changer
Cooling method: OFWF, Cooling medium: 25# Transformer Oil
Adopts double copper wall water cooler
Grounding shield between primary and secondary winding
With display thermometer device and alarm thermometer


Executive Standard
JB/T3837-96                Production Model Formation Method for Transformer
JB/T8636-97                Power Converter Transformer
GB1094.1-2-1996        Power Transformer
GB1094.3-5-2003        Power Transformer
JB5344.1-1991            General for Ore Furnace Transformer
JB/T 5344.1-2004        General for Submerged Furnace Transformer
JB/T 6303-2004           Technical Specification and Requirement for Calcium-Carbid Furnace Transformer

Site condition
1.Altitude Above sea level≤1000m
2. Max. Temperature: +40ºC, Min. Temperature: -25ºC, Max. daily temperature difference: 25ºC,Relative Temperature: 90%.
3.Max. wind speed :35m/s
4.Earthquake intensity: seismic acceleration ( Horizontal : 0.1g and Vertical: 0.2g simultaneously) the seismic force safety factor which transformer can support≥1.67.

Main structure features and protection
1.Wire inlet and outlet type: Wire inlet from the top tank cover, secondary wire outlet from side (inside delta)
2.Structure:Oil tank is cover type, core hanging free structure
3.Water cooler adopts stainless bolt spiral plate water cooler
4.Secondary wire leading out: Each phase of transformer has 4 water cooler tube
5.Oil tank uses folded plate, has advantages as high mechanical strength, good appearance, few welding line and no leakage
6.Sealing: secondary wire-out terminals adopt epoxy casting resin structure, Magnetic separation of double pressed plate, to make sure no leakage from wire-out terminals. Tank rim and hand hole adopt one formation acrylate rubber gasket which resistant high temperature, oil resistant, resistant to oxidation to make sure no leakage from sealing cover.
7.Oil drain valve is high quality copper valve. Butterfly valve for cooler is vacuum type.
8.Oil conservator: Full sealed oil conservator with rubber bag matched with magnetic type oil level gauge
9.Terminal box: Stainless material
10. Gas relay on the main oil tank for fault alarm, fault trip; adopts pointer type oil level gauge to indicate the high or low oil level alarm; Gas relay on On-load tap changer for fault trip; temperature thermometer adopts BWY-802A(4-20mA) has remote connector with display when oil temperature overheat will deliver alarm signal; pressure relief valve will deliver trip signal when the tank pressure is too high,
11.The primary of transformer installed with current transformer and matched with current converter
12.Earthquake intensity: seismic acceleration ( Horizontal : 0.1g and Vertical: 0.2g simultaneously) the seismic force safety factor which transformer can support≥1.67


Shenda quality management:
Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace

Rectifer Transformer 15000kVA/20kv for Medium Frequency Furnace
  • 100MVA/220KV power transformer --- short circuit test report from CESI Italy
  • 120MVA/33KV EAF transformer; 50MVA/69KV Oil power transformer; 10MVA/33KV Dry type transformer ---Type test report from KEMA Netherlands
  • 63MVA/110KV Power transformer ---short circuit Test report - Issued by CTQC China
  • 12.5MVA/22KV Rectifier transformer--- routine test - Issued by V-check Korea
  • ISO9001&ISO14001&OHSAS18001
  • Power transformer & Furnace transformer & dry type transformer & Reactor  ---CE
Factory documentation Model
1 Technical parameters
2 Outline drawing
3 Lifting diagram
4 Nameplate drawing
5 Control box drawing
6 Transportation diagram
7 Transformer install manual
8 Transformer operation / Maintenance instruction
9 Principles parts / components ex-work certification and operation instruction
10 Recommended spare part for 2-5 years operation depends on client requirement
11 Test reports (routine test / type test / special test)
12 Etc…

During the design process, client will be permitted to come to factory to take a supervision and guidance, manufacture and acceptance test.
We provide engineering services like pre-commissioning / commissioning / install and operation consult support / technicians training on site.
We provide after-sales service.
We provide 12 months warranty of quality and performance

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now