• IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
  • IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
  • IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
  • IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
  • IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
  • IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer

IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer

Application: Power
Certification: ISO9001-2000, ISO9001&14001 OHSAS18001 CSA CE V-Check IEC IEEE
Usage: Power
Brand: Shenda
Transport Package: Export Worthy Packing
Trademark: EACHER
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HKDSPZ-4200/110
Origin
Jiangshan, Zhejiang, China
Production Capacity
1000 Per Year

Product Description

SAF transformer basic info

1) Top 1 in China: 63MVA SAF trans. 
2) ISO9001,ISO14001,CE 
3) Apply for IEC, JB, ANSI 
4) Up to 110kV, 81MVA 
•Main function and features
Furnace transformers are separated with normal power transformer with its characteristic of massive secondary currents which are the main products of Shenda Electric with many advantages both on quality and price. As an example a 30MVA unit at 150V would result in a secondary current of 115 kilo ampere. For these high secondary currents special bushings are required to be connected to the bus-bars. These bushings are specified with very specific arrangements to suit the bus-bar arrangement and cooling system. Furnace bus-bar are mostly water-cooled. The cooler are either of the oil forced (OFAF) or Oil forced water OFWF).

IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer


Company Introduction

IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer

IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
Shenda ( In full: Shenda Electric Group Co.,Ltd.)  is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.).  Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.

Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC).
shendaelectric.en.made-in-china.com

Certifications
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.

A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test

C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).
Projects on Site
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer

IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
Packaging and transportation
IEEE IEC ISO CE 20 Years Professional Oil Immersed 4200kVA 110kv Submerged Furnace Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
26
Year of Establishment
2007-11-07