• 20kv Electric Oil Cooled/Immersed Power Transformer
  • 20kv Electric Oil Cooled/Immersed Power Transformer
  • 20kv Electric Oil Cooled/Immersed Power Transformer
  • 20kv Electric Oil Cooled/Immersed Power Transformer
  • 20kv Electric Oil Cooled/Immersed Power Transformer

20kv Electric Oil Cooled/Immersed Power Transformer

Application: Power
Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000, ISO9001
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
S9 S10 S11 S13 S9-M S10-M S11-M S13-M
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
U
Brand
Eacher
Service Condition
Indoor/Outdoor
Tap Changer
Nltc/Oltc
Cooling Type
Ofwf/Onan
Core Structure
Toroidal
High Voltage Range
20kv
Iron Core
Silicon Sheet
Loss
Low Loss
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan City, Zhejiang Province, China
Production Capacity
6000sets Per Year

Product Description

Product Description

20kv electric oil cooled/immersed Power transformer

20kv Electric Oil Cooled/Immersed Power Transformer

Introduction
    The performance of our S9 S10 S11 series 20kV and 35kV three-phase oil-immersed transformer conform to the standard of GB 1094-1996 "Power Transformer " and GB/T6451-2008 "Technical Parameter and requirements of Three-phase Oil-immersed Power Transformer". The iron core is made of quality cold -rolled silicon steel sheet , and the coil is made of quality oxygen-free copper, featuring good outlook and safe running . The products are widely used in power transmission and distribution of industrial and agricultural power networks.

Main function and features
     High reliability, advanced level of performances, reasonable economical indicators.

    The core joints are of stepped shape with this steps , and the surface of the core is coated with cured     paint to lower losses and noises.

    The winding has novel structure and its oil passage is reasonable designed composition. Its newly designed insulation structure helps enhance its mechanical strength and this short-circuit withstanding ability .

      The oil tank is in various types , all have good outlook .

Main Technical parameters for 20kv level,S11-M series distribution transformer

Rated Capacity (KVA)

Voltage combination

Connection
Symbol

No-load loss (W)

On-load loss(w) 75

No-load
Current %

Shirt-circuit Impedance
%

HV (kv)

Tapping range

LV (kv)

30

6
6.3
10
10.5
11

±5%
±2x2.5%

0.4

Yyn0
Dyn11

100

600

2.1

           4

50

130

870

2

63

150

1040

1.9

80

180

1250

1.8

100

200

1500

1.6

125

240

1800

1.5

160

270

2200

1.4

200

330

2600

1.2

250

400

3050

1.2

315

480

3650

1.1

400

570

4300

1

500

680

5100

1

630

810

6200

0.90

4.5

800

980

7500

0.80

1000

1150

10300

0.70

1250

1360

12000

0.60

1600
2000
2500

1640
1940
2300

14500
17140
20260

0.60
0.60
0.50

Note: we can design and manufacture special transformer as customers' requirements.
Ordering Instruction: 1.product model; 2.rated capacity; 3.voltage range; 4.regulation range; 5.frequency; 6.connection symbol; 7. technical requirements for special transformer.


Certifications
20kv Electric Oil Cooled/Immersed Power Transformer

Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics
20kv Electric Oil Cooled/Immersed Power Transformer
Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.

20kv Electric Oil Cooled/Immersed Power Transformer
Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.

20kv Electric Oil Cooled/Immersed Power Transformer
Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection

20kv Electric Oil Cooled/Immersed Power Transformer
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).

Packaging and transportation
20kv Electric Oil Cooled/Immersed Power Transformer



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
20kv Electric Oil Cooled/Immersed Power Transformer
Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance

20kv Electric Oil Cooled/Immersed Power Transformer

FAQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
26
Year of Establishment
2007-11-07