35kv 2500kva three phase two winding no load tap changing oil immersed power transformer
Specifications
1 power transformer
2 ISO9001,ISO14001,OHSAS 18001, CE
3 Apply for IEC, ANSI
4.KEMA
Introduction to Products
The performances of our S9,S10,S11 series 20KV and 35KV three-phase oil-immersed transformer conform to standards GB1094-1996 "Power Transformer" and GB/T6451-2008 "Technical Parameters and Requirements of Three-phase Oil-immersed Power Transformer". Its core is made of quality cold-rolled silicon sheet and is of a full-miter non-puncture structure and its coil is made of quality oxygen-free copper. It is artistic in appearance and sage in running and is widely used in transmission and distribution of industrial and agricultural networks.
Main Function and Features
High reliabity,advanced levelof performance,reasonable economical indicators
The core joints are of stepped shape with 3 steps,and the surface of the core is coated with cured paint to lower losses and noise.
The winding has novel structure and its oil passage is reasonable designed. Its newly designed insulation structure helps enhance its mechanical strength and the short circuit withstanding ability
The oil tank is in various types,all have good outlook.
Main Technical Parameters for 35kv level,S9,S10,S11 series power transformer |
|
|
|
|
|
|
Rated Power |
High Voltage |
H.V.Tap rang |
Low Voltage |
Connection Symbol |
Short-Circuit Impedance(%) |
No-load Loss(KW) |
On-Load Loss(KW) |
No-load Current(%) |
KV |
KV |
KV |
9type |
10type |
11type |
9type |
10type |
11type |
800 |
35 38.5 |
±5% ±2×2.5% |
6.3 6.6 10 10.5 |
Yd11 |
6.5 |
1250 |
1110 |
980 |
9900 |
9350 |
9350 |
1.05 |
1000 |
1490 |
1320 |
1160 |
12200 |
11500 |
11500 |
1 |
1250 |
1760 |
1570 |
1380 |
14650 |
13900 |
13900 |
0.9 |
1600 |
2130 |
1900 |
1660 |
17650 |
16600 |
16600 |
0.85 |
2000 |
2610 |
2320 |
2030 |
19350 |
18300 |
18300 |
0.75 |
2500 |
3150 |
2800 |
2450 |
20700 |
19600 |
19600 |
0.75 |
3150 |
7 |
3870 |
3440 |
3010 |
24300 |
23000 |
23000 |
0.7 |
4000 |
4640 |
4120 |
3610 |
28800 |
27200 |
27200 |
0.7 |
5000 |
5490 |
4880 |
4270 |
33000 |
31200 |
31200 |
0.6 |
6300 |
7.5 |
6570 |
5840 |
5110 |
36900 |
34900 |
34900 |
0.6 |
8000 |
Ynd11 |
9000 |
8000 |
7000 |
40500 |
38300 |
38300 |
0.55 |
10000 |
10620 |
9440 |
8260 |
47700 |
45100 |
45100 |
0.55 |
12500 |
8 |
12600 |
11200 |
10800 |
56700 |
53600 |
53600 |
0.5 |
16000 |
15300 |
13600 |
11900 |
69300 |
65500 |
65500 |
0.5 |
20000 |
18090 |
16100 |
14100 |
83700 |
79100 |
79100 |
0.5 |
25000 |
21510 |
19120 |
16730 |
99000 |
93500 |
93500 |
0.4 |
31500 |
25650 |
22800 |
20000 |
1E+05 |
112200 |
112200 |
0.4 |
Company Introduction
Shenda ( In full: Shenda Electric Group Co.,Ltd.) is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.). Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.
Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC).
shendaelectric.en.made-in-china.com
Certifications
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China
120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands
63MVA/110KV Power transformer short circuit test report
-issued by CTQC China
12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea
ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .
B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test
C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).
Projects on Site
Packaging and transportation