20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer

Product Details
Customization: Available
Application: Power
Phase: Three

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
26
Year of Establishment
2007-11-07
Find Similar Products

Basic Info.

Model NO.
SC(B)-160/20kv
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Shenda
Coil Struction
Toroidal
Place of Origin
Jiangshan,Zhejiang
Transport Package
Sea Worthy Packing
Specification
CE, ISO, IEC, GB, ANSI
Trademark
EACHER
Origin
Jiangshan City, Zhejiang Province, China
Production Capacity
6000 Sets Per Year

Product Description


20kv 160kva nltc SC(B) Type Cast resin Dry type Transformer
1)Low loss and low noise
2)highly withstands short-circuit and lightning impact
3)CE certification



Application Of Products

     Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin. Thanks to advanced technology, quality raw materials , scientific management, and perfect inspection means ,our products have the following features:

             The coil is reinforced with glass fiber and cast under vacuum with filler epoxy resin. It has good mechanical properties, is free of crack and inner bubble and has low local discharge, high reliability, and long service life.

              The high-and  low-voltage systems are cast under vacuum, thus the coil will not absorb moisture; the clamps of core are subjected to corrosion-resistant treatment and it may run under high temperature or other serious environments.

                Flame retardancy , explosion-proof and no environmental contamination. The insulating materials in the coil such as glass fiber are self-extinguishing and they will not cause fire by the arc resulted from short-circuit . The resin will not generate toxic or harmful gas under high temperature.

                 Gas duct is embedded inside it to enhance the radiation power and over-load capacity.

                   Low loss and low noise. The core is lapped with 45 full-miter  and the step-type lamination effectively improves distribution of magnetic flux at core corners, and greatly reduces the no-load loss and the nose level.

                  It highly withstands short-circuit and lightning impact.

                   Small in volume, light in weight, safe in running and free of maintenance.

                   As per users' requirements the transformer may be provided with casing and blower fan.



Main Technical Parameters for 20kV SC(B) -50-2500 type

 
Rated Power High Voltage H.V.Tap Rang Low Voltage Connection Symbol Short-Circuit Impedance No-Load Loss(W) On-Load Loss(W)(120ºC) No-Load Current Insulation Class Noise(dB) Weight(kg)
kVA kV kV % SC(B)9 SC(B)10 SC(B)9 SC(B)10 %
50 20             22          24 ±5%     ±2×2.5% 0.4 Yyn0    Dyn11 6 380 340 1300 1240 2.4 F 2.4 560
100 600 540 2100 2000 2.2 2.2 690
160 750 680 2600 2470 1.8 1.8 810
200 820 740 3100 2950 1.8 1.8 1030
250 940 850 3600 3420 1.6 1.6 1280
315 1080 970 4300 4090 1.6 1.6 1530
400 1280 1150 5100 4850 1.4 1.4 1660
500 1500 1350 6100 5800 1.4 1.4 2010
630 1700 1530 7200 6840 1.2 1.2 2390
800 1950 1760 8700 8270 1.2 1.2 3060
1000 2300 2070 10300 9790 1 1 3410
1250 2650 2390 12150 11540 1 1 4010
1600 3100 2790 14600 13870 1 1 5030
2000 3600 3240 17250 16390 0.8 0.8 5980
2500 4300 3870 20400 19380 0.8 0.8 6160
Certifications
20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer

Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics
20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer
Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.

20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer
Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.

20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer
Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection

20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer
Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).


Packaging and transportation
20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .
20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer
Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance

20kv 160kVA Nltc Sc (B) Type Cast Resin Dry Type Transformer

RFQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now